Rockylogic Driver Download For Windows



you are here: home > support > product notices

This page has Product Notices applying to the Ant8 and Ant16 logicanalyzers.

PN0103.1 Ant8 and Windows XP

Download the latest version of Double Driver for Windows. Create a security copy ofyour drivers. Sometimes, the task of updating your drivers can be very difficult. Need a Bluetooth Driver for your accessory? If you are having Bluetooth trouble, updates should be available through Microsoft's Windows Update service. If drivers were not downloaded automatically by Windows Update, use Device Manager to refresh the driver from Windows Update, or contact the device manufacturer. Select or enter your model to download drivers, firmware updates, BIOS & software. End of support notification for products using the Windows 7 operating system. Supported OS: Windows 10, Windows 10 1803+ Windows 10, Windows 10 1803+, Killer Wi-Fi 6 AX1650, Killer Wireless-AC 1550 Bluetooth for Killer 1650 & 1550 - Windows 10.

Download XGI graphics. Ant8 units shipped before the middle of 01/03 use a genericProduct ID in their USB interface. This can cause problems when workingwith Windows XP.Units shipped after this date use a product-specific Product ID anddo not manifest the problem.The problem only applies to systems using Windows XP.

Symptoms

When an Ant8 is plugged into a Windows XP system the devicemanager comes up with Install software for 'USB Serial Port',which cannot be found in the ant8/driver sub-directory.

Rectification

  1. Unplug the Ant8.
  2. Go to the control panel. Use add/remove programs to removethe FTDI VCP drivers.
  3. Disconnect from the internet. (XP can silently search the web fordrivers)
  4. Plug the Ant8 back in.
  5. Use the option Install from a Specific Location (Advanced)and browse to the location of the D2XX drivers on your system.

PN0403.1 Ant8 Input Pulldowns

Certain Ant8 units shipped between 2/03 and 4/03 may have incorrectpulldown resistors on the eight signal input circuits.

Symptoms

Weak driving circuits are unable to overcome the pulldowns.The user can easily check the values of the pulldowns as follows:

  1. Unplug the Ant8.
  2. Measure a pulldown resistance by measuring the resistance betweena red signal grabber and the black ground grabber.The measured value should be 100Kohm to 1Mohm.Repeat this measurement for all eight channels.

Rectification

Either replace the pulldowns with the correct values (100Kohm to 1Mohm)or remove the pulldown resistors. This is a job for a skilledtechnician and the small component sizes dictate the use of magnification.

Factory Rectification

If you believe your Ant8 has this problem, send an email describingthe problem and including the product serial number and approximatedate of purchase tosupport@rockylogic.com.

PN0403.2 Ant8 Input Circuit Frequency Response

Certain Ant8 units shipped between 12/02 and 4/03 may have incorrectbypass capacitors in the eight signal input circuits.

Symptoms

The Ant8 fails to respond accurately to slow signal edges (bothslow-rising and slow-falling). It also inaccurately measurespulses which are short in relation to the rising/falling times.

Rectification

The eight input bypass capacitors should be replaces by 220pFcapacitors (50V rated, 0402 size). This is a job for a skilledtechnician and the small component sizes dictate the use of magnification.

Factory Rectification

If you believe your Ant8 has this problem, send an email describingthe problem and including the product serial number and approximatedate of purchase tosupport@rockylogic.com.

PN0703.1 Ant16 Overheating

Some early Ant16 units, shipped in 6/03 or early 7/03, may havean incorrectly mounted tantalum capacitor.

Symptoms

The Ant16 works for a while, then fails to respond to the software.Typically the software then report the Ant16 as not present.

Rectification

The potentially reversed tantalum capacitor is on the PCB sidewhich does not have the LEDs. The cap should be mounted with thepolarity stripe towards the big flat pack - this can be checkedthrough the translucent plastic cover.The capacitor can be reversed by opening up the case(see Opening up),and unsoldering, reversing, resoldering the capacitor.Ideally the capacitor should be replaced with a new part(tantalum, case size A, approximately 3.3muF, 10V).

Factory Rectification

If you believe your Ant16 has this problem, send an email describingthe problem and including the product serial number and approximatedate of purchase tosupport@rockylogic.com.

PN0408.1 64-bit Vista Drivers

The 64-bit version of Windows Vista does not permit installationof the Ant drivers.

Symptoms

Windows refuses to install the Ant drivers because they are unsigned.

This only applies to users running the 64-bit version of Windows Vista,also known as the AMD64 version.It does not apply to 32-bit Windows Vista or to Windows XP.

Background

Every USB device is identified by a Vendor ID (VID) and a Product ID (PID).Our instruments use FTDI USB chips, and they use the FTDI VID, which is 0403.Standard FTDI chips have a PID of 6001; we reprogram the chips to ourown PID, which is F918.Since the FTDI chips are widely used in a variety of products, having ourown non-standard PID helps to avoid driver conflicts and to avoid the problemslisted in PN0103.1

We use standard FTDI binary drivers.However, the standard FTDI driver package is digitally signed to the 6001 PID,which does not match our F918 PID.Under Windows XP and Windows Vista 32, the effect of the non-match is a simple warningmessage when the drivers are installed.

Windows Vista 64 will not install a driver if the PID does not match thedriver digital signature.

Rectification

Rockylogic Driver Download For Windows

Change the PID back to the FTDI standard value of 6001.The driver digital signature will then match the PID and the driver will install.This is the procedure:

  1. Plug the Ant into a Windows XP system.
  2. Download and install the FTDI MPROG program:MProg3.0_Setup.exe.This program will reflash the PID.
  3. Download and unzip the latest FTDI drivers:here.
  4. Download the 6001 template for MPROG:rocky6001.eptYou may also wish to download the template for reverting the Ant to an F918 PID:rockyf918.ept
  5. Run MPROG. Use File|Open to load the template, then Device|Program toreflash the Ant.
  6. Exit MPROG. Unplug and replug the Ant to switch to the new PID.

The Ant will now report a standard FTDI VID/PID pair and the FTDI drivers will installon Vista 64.

Opening up an Ant8 or Ant16

Opening up

Rocky Logic Driver Download For Windows 7

Start where the plastic comes together round thecable. Carefully separate with a small screwdriver,then separate the rest of the casing.

Reassembling

Place the Ant8 or Ant16 in the plastic half whichdoes not have holes for the LEDs. Put the cable in place,taking care to position the small hole in thetranslucent cable gland over the small spike on the plastic.

Position the other half of the plastic enclosure sothat it also has its small spike engaged with ahole in the translucent cable gland. Bring the twoplastic halves together, starting with the locatingpegs nearest the cable and finishing with thelocating pegs nearest the clips connector.

Ethernet controller drivers download for windows 10 8.1 7 vista xp 32 bit. Jul 28, 2020 Realtek Ethernet Windows Driver 10.39.20 on 32-bit and 64-bit PCs. This download is licensed as freeware for the Windows (32-bit and 64-bit) operating system on a laptop or desktop PC from drivers without restrictions. Realtek Ethernet Windows Driver 10.39.20 is available to all software users as a free download for Windows.

-->

Applies to:SQL Server (all supported versions) Azure SQL DatabaseAzure SQL Managed InstanceAzure Synapse AnalyticsParallel Data Warehouse

The OLE DB Driver for SQL Server is a stand-alone data access application programming interface (API), used for OLE DB. OLE DB Driver for SQL Server is available on Windows and delivers the SQL OLE DB driver in one dynamic-link library (DLL).

Download

The redistributable installer for Microsoft OLE DB Driver for SQL Server installs the client components required during run time to take advantage of newer SQL Server features. Starting with version 18.3, the installer also includes and installs the Microsoft Active Directory Authentication Library (ADAL.dll).

Microsoft OLE DB Driver 18.5 for SQL Server is the latest general availability (GA) version. If you have a previous version of Microsoft OLE DB Driver 18 for SQL Server installed, installing 18.5 upgrades it to 18.5.

Download Microsoft OLE DB Driver for SQL Server (x64)
Download Microsoft OLE DB Driver for SQL Server (x86)

Version information

  • Release number: 18.5.0
  • Released: December 1, 2020

Note

If you are accessing this page from a non-English language version, and want to see the most up-to-date content, please visit the US-English version of the site. You can download different languages from the US-English version site by selecting available languages.

Available languages

This release of Microsoft OLE DB Driver for SQL Server can be installed in the following languages:

Microsoft OLE DB Driver 18.5 for SQL Server (x64):
Chinese (Simplified) | Chinese (Traditional) | English (United States) | French | German | Italian | Japanese | Korean | Portuguese (Brazil) | Russian | Spanish

Microsoft OLE DB Driver 18.5 for SQL Server (x86):
Chinese (Simplified) | Chinese (Traditional) | English (United States) | French | German | Italian | Japanese | Korean | Portuguese (Brazil) | Russian | Spanish

Release notes

Rockylogic Driver Download For Windows

For details about this release, see the release notes.

Previous releases

See also

Release notes for the Microsoft OLE DB Driver for SQL Server
System requirements for OLE DB Driver for SQL Server
Support policies for OLE DB Driver for SQL Server
When to use OLE DB Driver for SQL Server
Installing OLE DB Driver for SQL Server